14. Setting Switch

Performs the following settings:
• Data communications address (0 – 3)
• Number of group keys (0, 10, or 20)
• Microphone compressor (ON/OFF)

[Default settings]
Data communications address: 0
Number of group keys:

0

Microphone compressor:

ON

15. FS-7010RM Connection Terminal

Connect the FS-7010RM to this terminal to
increase the number of zone selector keys.

16. DC Power Supply Input Terminal

Connect this terminal to an AC adapter.

17. USB Terminal

Not used.

18. FS-7000RF Link Terminal

Connect this terminal to the FS-7000RF.

19. Microphone Volume Control

Adjusts the volume of the Microphone (13) and
External Microphone (20).

20. External Microphone Input

Connect this terminal to an external microphone.
(–40 dBV, 2.2 kΩ, unbalanced, mini-jack,
w/phantom power supply)