Refer ence man ual, Wir eless fuzzyscan, Use fuzzyscan in pair mode – Cino PL680BT HC User Manual

Page 14

Advertising
background image

W

ir

eless FuzzyScan

R

efer

ence Man

ual

Getting Started

6

Use FuzzyScan in PAIR Mode

Ensure the battery is fully charged. You may refer to the section of Preparations before Using for details.

Please choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to
the host device.

Turn on the power of your host device.

Power on or wake up the scanner by pressing the Trigger key if the scanner is power-off or in sleep state.

This scanner is pre-paired with the shipped smart cradle, so you will see the link indicators of scanner blink blue per 2.5
seconds
, and the central indicator of the smart cradle light blue. If the scanner and smart cradle are not paired, the
status indicator of scanner and the side indicators of smart cradle blink red and green alternatively (in “Uninstall” state).
Please follow step 6 to establish the connection.

Scan “PAIR mode” command. The status indicator of scanner will turn steady red immediately.

Uninstall

PAIR Mode

Place the scanner on the smart cradle, then you will hear one short beep to indicate the pairing process is activated. The
scanner will emit continuous short clicks and the link indicator of scanner will flash blue quickly during the pairing process.
When you hear 4 beeps in ascending tone, the pairing process is completed. You will see that the link indicator of scanner
gives 1 blue blink per 2.5 seconds and the central indicator of the smart cradle lights blue.

If the scanner pairing process failed or it’s not placed on the smart cradle within 20 seconds, you will hear 2 “Di-do Di-do”
beeps to warn the failure of pairing, the scanner will return to uninstall state automatically.

Scan the corresponding host interface quick set command to complete the installation.

The default host interface of smart cradle is preset to USB HID. If you want to set the host interface to USB COM, you
have to install the USB virtual COM driver into your host device before using the scanner. Please visit CINO website to