W

ir

eless FuzzyScan

R

efer

ence Man

ual

Configure Your FuzzyScan

32

PROGRAM

Symbology Reading Control

UPC-A & UPC-E Setting

F_DEFAULT

Family Code Selection

P.C

Parameter Selection

Option Code

UPC Family Setting

SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS

Disable UPC-A
Enable UPC-A
Disable UPC-E
Enable UPC-E
Disable UPC-E expansion
Enable UPC-E expansion
Disable UPC standardization
Enable UPC standardization
Disable UPC numeric system
Enable UPC numeric system
Disable UPC-A check digit transmission
Enable UPC-A check digit transmission
Disable UPC-E check digit transmission
Enable UPC-E check digit transmission
Disable UPC “leading 1” portion
Enable UPC “leading 1” portion

0
1
2
3
4
5
6
7
8
9

A
B
C
D
E
F

When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric
system, UPC-A check digit transmission.

UPC-E & EAN-8 Expansion

: Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.

UPC-A/E Standardization

: Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.

UPC Lead 1 Numeric System

: Enable to read UPC leading with the 1 numeric system, you must enable this option.

WPC Selection

(UPC/EAN/CAN)

Basic Length

Disable

Check Digit

Disable

Numeric System

With 2-digit

Addendum

With 5-digit

Addendum

Enable

Standardization

Enable

Expansion

UPC-A

12

- 1

- 1

+ 2

+ 5

+ 1

0

UPC-E

8

- 1

- 1

+ 2

+ 5

+ 1

+ 4

EAN-13

13

- 1

NC

+ 2

+ 5

NC

0

EAN-8

8

- 1

NC

+ 2

+ 5

NC

+ 5