Refer ence man ual, Wir eless fuzzyscan – Cino PL680BT HC User Manual

Page 77

Advertising
background image

W

ir

eless FuzzyScan

R

efer

ence Man

ual

Configure Your FuzzyScan

69

The breakdown of the command line is shown below:

03

The number of elements in the overall rule

01

Code identifier of Code 128

0010

Code length that must match for Code 128
A-CODE128 sample length (9) plus Suffix Symbol ID (1) = 10

41

Start character match for Code 128, 41h = “A”

FF

End of first code

07

Code identifier of Code 39

0009

Code length that must match for Code 39
B-CODE39 sample length (8) plus Suffix Symbol ID (1) = 9

FF

Universal matched character, indicating all character
Also indicate end of second code

09

Code identifier of Code 93

0009

Code length that must match for Code 93
C-CODE93 sample length (8) plus Suffix Symbol ID (1) = 9

43

Start character match for Code 93, 43h = “C”

FF

End of third code

Note: If the [Character match(es)] is set to “FF”, the following “FF” which indicated the end of the code was not need to set.

-

Structure of Data String

STX

(RS232/USB COM

interface)

Preamble Scanned

Data

Length

Prefix Symbol ID

Or

Prefix AIM Symbol ID

Scanned Data modified

by DataWizard

Suffix Symbol ID

Or

Suffix AIM Symbol ID

Postamble

ETX

(RS232/USB COM

interface)

1 character

1-15 characters

2-4 digits

1 or 3 characters

Variable length

1 or 3 characters

1-15 characters

1 character





Advertising