Multimeter Tests

96

MAX-635

Voltage

Continuous AC Page

The Continuous AC function measures each pair,
displaying and updating results in real time, until you
stop the test. The last valid results then remain
displayed.

Continuous AC and Continuous DC are run
synchronously.

Press Start/Stop on the keypad to run the test.

Current Group is the current test group name, for
example Multimeter.

Current Test displays the test being measured.
Here you can switch to another test from the given list. However, this
action will terminate the ongoing measurement test.

Selected Pair allows you to select All Pairs or a single wire pair for
measurement.

Termination Resistance defines how much resistance the tester uses
to connect to the line and measure voltages.

Threshold Settings button opens a new page that allows you to set the
AC voltage thresholds for each pair.

Result displays a snapshot of the pass/fail status, volts and frequency
(Hz) values for each continuous AC pair.

Test Status displays the current state of measurement or an error
message.