EXFO MaxTester 635 User Manual

Page 259

Advertising
background image

Setting Up DSL/IP Tests

Copper and VDSL2/ADSL2+ Multi-play Test Set

251

Test Configuration

ADSL2Multi (xA/P2) - support G.dmt and T1.413 only.

VDSL Bonding - if VDSL2 and Bonding options are enabled.

VDSL2-30a (P1) - if VDSL2 option is enabled.

Annex M allows you to Enable/Disable this option when Test
Interface
is ADSL2+ (xA/P2) or VDSL2/ADSL2+ (xA/P2).

Annex J allows you to Enable/Disable this option when Test Interface
is ADSL2+ (xB/P1) or VDSL2/ADSL2+ (xB/P1).

ADSL Transport displays the transport type options: PTM (packet
transfer mode), ATM (asynchronous transfer mode), or ATM and PTM.

Access Mode options are dependent on the Test Interface selection:

If ADSL2+, ADSLMulti, and VDSL2/ADSL2+- available options are
Sync Only, Bridged (not in Auto Test), DHCP, Static, PPPoE, PPPoA,
IPoA.

If ADSL2+ Bonding and VDSL2 Bonding - available options are
Sync Only, Bridged (not in Auto Test), DHCP, Static, PPPoE.

For Ethernet - available options are Bridged, DHCP, Static, PPPoE.

Auto Resync allows you to Enable the SyncLossCounter as the
Pass/Fail criteria. When SyncLossCounter+1 is reached, the test will
have fail status.

If Auto Resync is disabled, any time the test loses sync, the result status
will be fail and the test will stop automatically.

Sync Timeout Period enables you to enter the duration, between
2 and 30 minutes, to run a DSL test from activation to reaching
Show Time.

Keep Sync Time is either:

Continuous where the test runs until you manually stop it, or

User Defined where you can set a Keep Sync Time Period.
Default is 5 minutes.

Advertising