Faultmapper result details – EXFO MaxTester 635 User Manual

Page 146

Advertising
background image

SmartR™ Features

138

MAX-635

FaultMapper

FaultMapper Result Details

The Result Details read-only page displays the test
results in text and graphical format.

Test Identification is the name of the test, for
example FaultMapper.

Cable Setup button opens a new page displaying
the cable parameters of the test. Use the left/right
arrows to select the button and press

to open

the page.

Result displays the cable fault details.

Note: Some displayed resistive faults may be effective faults.

For example if a strap is present, a T-G short may be shown twice: first as a
T-G short and second as an
effective R-G short. In such cases, the
resistance shown is the resistance that would be measured using a
multimeter.

Estimated Length displays the cable length when the cable is open.

Fault Status displays the number of faults detected (or No fault
detected
) after running the test.