Rfl cable setup – EXFO MaxTester 635 User Manual

Page 226

Advertising
background image

RFL

218

MAX-635

RFL Cable Setup

RFL Cable Setup

The Cable Setup page allows you to set cable
parameters for an RFL test. Settings are shared by
both Single Pair and Separate Good Pair tests.
Changes done in Cable Setup for one test are
reflected in the other.

No. of Cable Sections allows you to set the
number of consecutive cable sections, to a
maximum of 5. If unknown, set the number to 1.

Cable Type allows you to select a cable entry
(with its associated parameters) from the current
Cable Book, to use for testing. The selection is not
saved when leaving the test. The current Cable Book entry is shown by
default.

Resistance specifies a value for the resistance constant of the cable in
each section.

Section Length allows you to specify the cable length of each section.
If the cable length is unknown, specify 0 and the RFL test will measure
the length.

Load Coil allows you to set the detection of the presence of load coils
to either Yes or No.

Cable Temperature allows you to change the temperature of the cable
under test in either degree C or F.

Advertising