Multimeter Tests

Copper and VDSL2/ADSL2+ Multi-play Test Set

115

Capacitance/Opens

Capacitance T/R to GND displays the capacitance value from Tip
or Ring to Ground, in nF/mi ranging from 10.0 to 500.0.

Threshold Settings button opens a new page that allows you to set the
capacitance/opens threshold for the test.

Result displays a snapshot of the pass/fail status, Capacitance and
Length for each selected wire pair. Capacitive Balance is shown in %
when All Pairs are selected.

Test Status displays the current state of measurement or an error
message.

To select the parameter values:
1.
Press the up/down arrow keys to highlight the desired parameter.

2. Press the left/right arrow keys to view and select the options.

OR

3. Press

on a value to open a list box of options and use the navigation

keys to scroll through.

4. Press

to confirm the value.

Continuous

The Continuous function measures each pair,
displaying and updating results in real time, until you
stop the test. The last valid results then remain
displayed.

Current Group is the current test group name, for
example Multimeter.

Current Test displays the test being measured.
When FED is Enabled, the FED icon and numeric
state are displayed beside the Current Test.
Here you can switch to another test from the given
list. However, this action will terminate the
ongoing measurement test.