Capacitance/opens threshold settings – EXFO MaxTester 635 User Manual

Page 125

Advertising
background image

Multimeter Tests

Copper and VDSL2/ADSL2+ Multi-play Test Set

117

Capacitance/Opens

Capacitance/Opens Threshold Settings

The Threshold Settings page allows you to set the
Capacitive Balance Threshold parameters for the
test between 0 and 100 %.

Type is the threshold limit for each pair: either
Maximum or Minimum.

Enabled is a flag to use the current threshold:
either Yes or No.

To set threshold values:
1.
Press the up/down arrow keys to highlight the

desired parameter.

2. Press the left/right arrow keys to view and select the options.

OR

3. Press

on a value to open a list box of options or the alphanumeric

editor screen and use the navigation keys to scroll through.

4. Press

to confirm the value.