Faultmapper – EXFO MaxTester 635 User Manual

Page 143

Advertising
background image

SmartR™ Features

Copper and VDSL2/ADSL2+ Multi-play Test Set

135

FaultMapper

FaultMapper

The FaultMapper test allows you to locate and
identify service-affecting line faults using TDR (time
domain reflectometry) and RFL (resistance fault
locator) technology. This test is useful in locating
bridged taps, shorts, grounds, and opens.

Current Test displays the test being measured.

Far End Strap allows you to select option Yes or
No for use of a strap.

A strap, while not required, enables FaultMapper
to calculate distance to a ground/earth fault.

Cable Setup button opens a new page that allows
you to set the Cable Parameters for the Current Test.

Result displays the cable faults in text and graphical format.

Note: Some displayed resistive faults may be effective faults. For example if a

strap is present, a T-G short may be shown twice: first as a T-G short and
second as an
effective R-G short. In such cases, the resistance shown is the
resistance that would be measured using a multimeter.

Estimated Length displays the cable length when the cable is open.

Note: The cable length may include the Bridge Tap length. Remove the Bridge Tap

for better accuracy.

Fault Status displays the number of faults detected (or No fault
detected
) after running the test. The status Open detected is reported
in the following case:

No strap.

The pair is open.

No faults (other than the pair being open).

Advertising