Resistive balance, Snapshot – EXFO MaxTester 635 User Manual

Page 115

Advertising
background image

Multimeter Tests

Copper and VDSL2/ADSL2+ Multi-play Test Set

107

Resistive Balance

To select the parameter values:
1.
Press the up/down arrow keys to highlight the desired parameter.

2. Press the left/right arrow keys to view and select the options.

OR

3. Press

on a value to open a list box of options or the alphanumeric

editor screen and use the navigation keys to scroll through.

4. Press

to confirm the value.

Resistive Balance

The Resistive Balance test measures and compares the resistance of each
leg. This test requires you to short Tip and Ring (T-R) to ground at the far
end (T-R-G short) before proceeding with the test.

Snapshot

The resistive balance Snapshot shows results for
R-Leg, T-Leg, Loop resistance, and the pass/fail status
for Resistive Balance in

and %. Parameters are as

follow:

Current Group is the current test group name, for
example Multimeter.

Current Test displays the test being measured.
When FED is Enabled, the FED icon and numeric
state are displayed beside the Current Test.
Here you can switch to another test from the given
list. However, this action will terminate the
ongoing measurement test.

Advertising