Sb065: feedback loop monitoring, Intended use – Pilz PSS SB NOT, Basic license User Manual

Page 26

Advertising
background image

4-4

Intended Use

Modular Block System: Emergency Stop Circuits

• With or without automatic reset when E-STOP is released

• With or without prompt for function test after a synchronisation error

when the E-STOP is released

INFORMATION
Input circuitry:

• Use E-STOP button with test pulses

• When using SB063 for category 4 applications:

- use dual-channel elements

• When using SB063 for category 2 applications:

- use single-channel elements

SB065: Feedback loop monitoring

SB065 is a standard function block for the direct control and monitoring of 1
or 2 contactors up to category 4, in accordance with EN 954-1, 03/97.

INFORMATION
On SB065, the SSNR may lie in the range of 1 to 600.

Features and application areas:

• Feedback loop is monitored during the change in the switch signal and

while the contactors are in a static condition.

• Feedback loop can be monitored on two separate feedback loops of

contactors connected in series

• Feedback loop can be monitored on two separate feedback loops of

contactors connected in parallel

• Feedback loop can be monitored on group contactors

• Selectable time for feedback loop monitoring

• Parameter to suppress error messages when an I/O-Group stops

(SafetyBUS p)

INFORMATION
Input circuitry:

• To achieve category 4, two independent shutdown routes must be

provided within the current path of the potentially dangerous drive

Advertising