5-5

Modular Block System: Emergency Stop Circuits

Blocks contained in the administration data blocks

Each standard function block occupies 1 data word per block (see
Fig. 5-2). This means a max. of 200 safety devices (e.g. E-STOP 1, E-
STOP 2, safety gate 1) can be managed per administration data block.

The PSS uses a standard function block’s SSNR to automatically generate
the corresponding data words (see section entitled “Input parameter
SSNR”).

DB017

DB016

DW0000

DB015

Block 1

Block 2

Block 3

Block 4

Block 5

Block 6

Global

parameters

Data word 1

Data word 2

Data word 3

Data word 4

Data word 5

Data words 1 to 5

of an MBS

standard function block

Fig. 5-2: Contents of the administration data blocks