Error messages – Pilz PSS SB NOT, Basic license User Manual
Page 71
Modular Block System: Emergency Stop Circuits
6-29
Error messages
Any fault that is detected will be stored in the corresponding error data
word (
SSNR) of DB015 (1st data block), until the fault has been fully dealt
with.
• Error messages in DB015
- Bit 00: Faults which occur as the pulse edge changes at the input
parameter
EIN
RFK 1 remains open
Remedy: Check contacts, cable, input card and all conditions
and then reset (input parameter
RSET)
- Bit 01:
Faults which occur as the pulse edge changes at the input
parameter
EIN
RFK 1 remains closed
Remedy: Check contacts, cable, input card and all conditions
and then reset (input parameter
RSET)
- Bit 02:
Faults which occur as the pulse edge changes at the input
parameter
EIN
RFK 2 remains open
Remedy: Check contacts, cable, input card and all conditions
and then reset (input parameter
RSET)
- Bit 03:
Faults which occur as the pulse edge changes at the input
parameter
EIN
RFK 2 remains closed
Remedy: Check contacts, cable, input card and all conditions
and then reset (input parameter
RSET)
- Bit 04:
Faults which occur as the pulse edge changes at the input
parameter
EIN
RFK 1 interrupted
Remedy: Check contacts, cable, input card and all conditions
and then reset (input parameter
RSET)
- Bit 05:
Faults which occur as the pulse edge changes at the input
parameter
EIN
RFK 1 closed
Remedy: Check contacts, cable, input card and all conditions
and then reset (input parameter
RSET)