Modular Block System: Emergency Stop Circuits

Standard Function Blocks

Global parameters used in administration data block DB 015

Global parameters may be set with SB070 in OB120.
• DW1015: Counter for monitoring the

SSNR

INFORMATION
On some blocks (e.g. E-STOP) the input parameter

SSNR is monitored.

These blocks must be run through as part of each PSS-cycle. The
following commands should therefore be entered once only at the end of
OB101:

A

DB015

I

DW1015

Effect:
The counter for monitoring the

SSNR in DB015/DW1015 (global

parameters) will be incremented.

Blocks required

• DB015:

Administration data block

DB015 must consist of its total length of 1024 data words.
DB015 must have READ/WRITE access.

• SB070

Initialisation of global parameters in DB 015

• SB255:

To call up the operating system