Modular Block System: Emergency Stop Circuits
Standard Function Blocks
SB070
Please note:
Entering excessively high time values for monitoring operations will reduce
the safety level of your machine.
If you are using type 2 ESPE/AOPD devices, a maximum value of 150 ms
may be entered for parameter
RBWS (EN 61 496-1).
• The number of cycles calculated is rounded down and transmitted to the
data words in administration data block DB 015.
• The SB must be called up once only when the PSS is started up
(e.g. in OB120).
Error messages
• None
Blocks required
• OB120
• DB015:
Administration data block
DB015 must consist of its total length of 1024 data words.
DB015 must have READ/WRITE access.