Trs aligner, Trs aligner -23 – Altera SDI II MegaCore User Manual

Page 65

Advertising
background image

TRS Aligner

The TRS aligner word aligns the descrambled receiver data until the bit order of the output data and the

original video data are the same. The EAV and SAV sequences determine the correct word alignment.

Table 4-4: EAV and SAV Sequences

Table below lists the sequence pattern for each video standard.

Video Standard

EAV and SAV Sequences

SD-SDI

3FF 000 000

HD-SDI

3FF 3FF 000 000 000 000

3G-SDI Level A

3FF 3FF 000 000 000 000

3G-SDI Level B

3FF 3FF 3FF 3FF 000 000 000 000 000 000 000 000

6G-SDI Level A

3FF 3FF 3FF 3FF 000 000 000 000 000 000 000 000

6G-SDI Level B

3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 000 000 000 000 000 000 000 000

000 000 000 000 000 000 000 000

12G-SDI Level A

3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 000 000 000 000 000 000 000 000

000 000 000 000 000 000 000 000

12G-SDI Level B

3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF 3FF

000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000

000 000 000 000 000 000 000 000 000 000 000 000 000 000 000

The TRS aligner matches the selected pattern in the descrambled receiver data. If the aligner detects a

pattern at any of the possible word alignments, it raises a flag and indicates the matched alignment. This

process applies continuously to the receiver data.
In the second stage, the TRS aligner determines the correct word alignment for the data. The aligner looks

for three consecutive TRSs with the same alignment and then stores that alignment. If the aligner

subsequently detects two consecutive TRSs with a different alignment, then it stores this new alignment.
In the final stage, the TRS aligner applies a barrel shift function to the received data to generate the

correctly aligned parallel word output. The barrel shifter allows the design to instantly switch from one

alignment to another.
For 6G-SDI and 12G-SDI video standards, these submodules have an additional function to restore the

correct TRS words. The submodules restore the correct TRS words from the data inserted through sync

bits.

UG-01125

2015.05.04

TRS Aligner

4-23

SDI II IP Core Functional Description

Altera Corporation

Send Feedback

Advertising