Casella CEL CEL-310 User Manual

Page 37

Advertising
background image

With 12 hours of 1 minute Time History

Up to 128 Measurements

With 8 hours of 1 minute Time History

Up to 186 Measurements

Weightings:

Frequency

A for all Sound Level measurements.

C for Peak Sound Pressure.

Time

None as standard.

S (slow) for OSHA Version.

Dose Badge Configuration:

Criterion Level

User Selectable 80 dB, 85 dB, 87 dB, 90 dB,

Criterion Time

8 hours, 12 hours, 16 hours, 18 hours,

Threshold

None (ISO), 80 dB (OSHA),

Peak Threshold

Factory configured to 140 dB,

137 dB(C) or 134 dB(C) Peak Option.

Power:

Dose Badge

Internal NiCad battery with intelligent charging system.

Reader

2 x AA (LR6 / AM3 / MN1500 / Mignon).

The memory and clock of the Reader are protected

for up to 10 minutes when the main batteries are

removed.

Calibration:

Via internal Acoustic Calibrator to IEC 61942:1998 Class 1L.
Level: 114 dB,

Frequency :1 kHz.

Output:

Dose Badge

Infrared to Reader Unit,

Reader

RS232 via Mini-Din connector.

Dimensions:

Dose Badge

Microphone Apex 12.7mm,

Base 47 mm,

Height 30 mm,

45 g (1.6 oz).

Reader

160 mm x 80 mm x 38 mm,

400 g (14 oz).

Environmental:

Temperature

-10

o

C to +50

o

C Operating,

-20

o

C to +60

o

C Storage.