AMETEK SL Series Calibration Manual User Manual

Page 31

Advertising
background image

Elgar Electronics Corporation

Calibration

2.5.4

CR M

ODE

, L

EVEL

H

IGH

, R

ANGE

II O

FFSET AND

G

AIN

, I

TEMS

27

AND

28

1.

LOAD OFF.

2.

Press the

© key to go to Item 27.

3.

Set the power supply voltage and the DC Voltage Standard to the
VSENSE Input value shown in Table 2-27 for the model being
calibrated.

4.

PRES ON.

5.

Set the current to the Current Setting value in Table 2-27 for the
model being calibrated.

6.

PRES OFF.

7.

LOAD ON.

8.

Adjust using the

…† keys until the DAM reading and the current

setting match.

MODEL

Resistance Setting VSENSE Input Current Setting

SLM-60-30-150 0.1068Ω 3.204V

30.000A

SLM-60-60-300 0.0534Ω 3.204V

60.000A

SLM-250-10-300 1.3334Ω 13.334V

10.000A

SLM-500-10-300 2.680Ω 26.80V

5.000A

SLM-60-15-75 0.2134Ω 3.201V

15.000A

SLH-60-120-600 0.0268

Ω 3.216V

120.00A

SLH-60-120-1200 0.0268

Ω 3.216V

120.00A

SLH-60-120-1800 0.0268

Ω 3.216V

120.00A

SLH-60-240-1200 0.0133

Ω 3.216V

240.00A

SLH-60-240-1800 0.0134

Ω 3.216V

240.00A

SLH-60-360-1800 0.0088

Ω 3.168V

360.00A

SLH-500-60-1800 0.4444Ω 26.666V 60.00A

Table 2-27. CR Mode, Level High, Range II Offset Adjustment Settings (Item 27)

9.

LOAD OFF.

10.

Press the

© key to go to Item 28.

SLM/SLH Calibration Manual

2-23