Operation Section

21

(3) Operation

1) Start of compression

1) The cylinder is filled with low pressure gas.

2) Since pressure in the discharge chamber is

higher than in the cylinder, the discharge

valve is kept closed.

2) Suction and compression

1) The pressure in the cylinder increases

gradually.

2) Refrigerant suction begins on the suction

side of the cylinder.

3) The discharge valve remains closed.

3) Discharge

1) The pressure in the cylinder exceeds that in

the discharge chamber, and the discharge

valve opens.

2) On the suction side, refrigerant suction

continues.

4) Completion of compression

1) When compression is completed, all of the

refrigerant has been drawn from the suction

chamber.

2) Operation then returns to step 1) (Start of

compression) and the above process of

suction and compression continues

repeatedly in succession.

I001676

Blade

Discharge

Valve

Roller

I001677

Blade

Discharge

Valve

Roller

I001678

Blade

Discharge

Valve

Roller

I001679

Blade

Discharge

Valve

Roller