6.6 Compressor Overload Relay

• An external compressor overload relay is used

to protect the compressor motor. This relay is

mounted within the connector housing that

attaches to the top of the compressor. The

relay interrupts the flow of current when there

is an overload condition and, high temperature

builds up in the compressor.

6.7 Power Cord with LCDI

• This unit is equipped with a UL recognized LCDI cord and NEMA plug configuration (5-15). The

appropriate outlet must be used for this plug type. LCDI is used for monitoring leakage current.

Once leakage current is detected, LCDI de-energizes the unit.

Operating Temperature

Non-Operating Limit at 176 °F

(100 °C) (A)

Marking

OFF (Open Contacts)

ON (Closed Contacts)

302 °F (150 °C)

156 °F (69 °C)

19.0

MRA4720-12027

I001691

Bimetal

Terminal

Points

I002239

Test Button

Reset

Button