background image

Repair Section

53

4) Remove thirteen (13) screws from the rear panel.

5) Open the faucet handle to supply water.

6) Insert screwdrivers under both sides of the valve

spring guide of the water regulating valve and lift

upwards to flush. This manual flushing does not

affect valve adjustment.

CAUTION

• Do not move the adjusting bolt.

• Take caution to prevent any corrosion inside

the copper tube if cleanser is used to clean the

water line.

7) Keep flushing the water inside the water line

through the drain until the water is clear.

8) Disconnect tap water from the water inlet and

outlet of the unit.

ILL00148-00

Screws (7)

Screws (3)

Screws (3)

ILL00159-00

Valve Spring
Guide