Repair Section

75

(2) Removal of gauge manifold

1) Crimp the pinch-off tube with a pinch-off tool.

2) Remove the gauge manifold and the process

tube fitting. Crush the end of the pinch-off tube.

3) Braze the end of the pinch-off tube.

4) Ensure that a gas leak is not present at the

pinched off portion and the brazed end.

I002185

Pinch-Off Tube

Pinch-Off Tool

Process Tube Fitting

Charging Hose

To Gauge

Manifold Side

To Refrigerant

Cycle Side