MovinCool Office Pro W20 Service Manual User Manual

Page 45

Advertising
background image

Repair Section

45

Control

panel

display

turns on

Control

Panel

display

shows error

codes.

3. Display code “RT”.

Loose room thermistor

connection.

Reconnect the room

thermistor and check the

connection.

RESET the controller

*1

.

Defective room thermistor

(short or open).

Replace room thermistor.

4. Display code “FT”.

Loose freeze protection

thermistor connection.

Reconnect the freeze

protection thermistor and

check the connection.

RESET the controller

*1

.

Defective freeze protection

thermistor (short or open).

Replace freeze protection

thermistor.

5. Display code “HP” and

“FAIL HP”.

Operating outside of the

operating temperature

range.

Check environmental

condition. Do not use the unit

outside the operating

condition range.

(See page 9.)

RESET the controller

*1

.

Insufficient water flow.

Connect water inlet of the unit

and water supply line

correctly.

RESET the controller

*1

.

Adjust flow of the supplied

water source. (See page 52).

RESET the controller

*1

.

Clean water system to

remove accumulated

sediment.

(See page 52 and 53.)

RESET the controller

*1

.

Loose high-pressure switch

connection.

Reconnect the high-pressure

switch and check the

connection.

Defective high-pressure

switch (short or open).

Replace high-pressure

switch.

Refrigerant is over charged.

Charge correct amount of

refrigerant. (See page 74.)

RESET the controller

*1

.

Condition

Check Area

Possible Cause

Remedy

Unit does not operate.

*1 : To RESET the controller, press ON/OFF and HI/LO buttons simultaneously for 5 seconds.

Advertising