Pacific Research Solutions RI-1 User Manual

Page 44

Advertising
background image

Pacific Research Solutions

RI-1 and PE-1 User Manual

Page 38

Tone Generator Command List

TONE GENERATOR COMMAND TABLE

Data Operation

Data Operation

Data Operation

00

Reset tone generator

34

Set TG Level 8

68

CW “Q”

01

Start Of Message

35

Set TG Level 9

69

CW “R”

02

End Of Message

36

Set TG Level 10

70

CW “S”

03

TG1, Tone generator off

37

CW speed, 5 WPM

71

CW “T”

04

TG1, Tone at 500 Hz

38

CW speed, 10 WPM

72

CW “U”

05

TG1, Tone at 600 Hz

39

CW speed, 15 WPM

73

CW “V”

06

TG1, Tone at 700 Hz

40

CW speed, 20 WPM

74

CW “W”

07

TG1, Tone at 800 Hz

41

CW speed, 25 WPM

75

CW “X”

08

TG1, Tone at 900 Hz

42

CW “0”

76

CW “Y”

09

TG1, Tone at 1000 Hz

43

CW “1”

77

CW “Z”

10

TG1, Tone at 1200 Hz

44

CW “2”

78

CW Space

11

TG1, Tone at 1400 Hz

45

CW “3”

79

CW “+”

12

TG1, Tone at 1600 Hz

46

CW “4”

80

CW “-“

13

TG1, Tone at 2000 Hz

47

CW “5”

81

CW “(“

14

TG1, Tone at 2500 Hz

48

CW “6”

82

CW “=”

15

TG2, Tone generator off

49

CW “7”

83

CW Comma “,”

16

TG2, Tone at 500 Hz

50

CW “8”

84

CW Period “.”

17

TG2, Tone at 600 Hz

51

CW “9”

85

CW “/”

18

TG2, Tone at 700 Hz

52

CW “A”

86

CW “?”

19

TG2, Tone at 800 Hz

53

CW “B”

87

CW Colon “:”

20

TG2, Tone at 950 Hz

54

CW “C”

88

CW Semicolon “;”

21

TG2, Tone at 1000 Hz

55

CW “D”

89

CW “)”

22

TG2, Tone at 1200 Hz

56

CW “E”

90

CW “@”

23

TG2, Tone at 1400 Hz

57

CW “F”

91

Tone off

24

TG2, Tone at 1600 Hz

58

CW “G”

92

Tone on

25

TG2, Tone at 2000 Hz

59

CW “H”

93

Delay for 10 ms

26

TG2, Tone at 2500 Hz

60

CW “I”

94

Delay for 20 ms

27

Set TG Level 1

61

CW “J”

95

Delay for 50 ms

28

Set TG Level 2

62

CW “K”

96

Delay for 100 ms

29

Set TG Level 3

63

CW “L”

97

Delay for 200 ms

30

Set TG Level 4

64

CW “M”

98

Delay for 500 ms

31

Set TG Level 5

65

CW “N”

99

Delay for 1000 ms

32

Set TG Level 6

66

CW “O”

33

Set TG Level 7

67

CW “P”

Reset Tone Generator Command
The “Reset Tone Generator” command performs the following functions:
• Set TG1 = 1000Hz

• Set TG2 = Off

• Set Level = 4

• Set CW Speed = 15wpm


It is good practice to always reset the Tone Generator in all of your CW messages. You can also set each of the 4 items listed
above in your message. If you do not address these items, their settings will be left over from the previous message played.

Advertising
This manual is related to the following products: