Page 42

S-Cmd 42 REGULAR INTERVAL EVENT

This command is used to configure a timer that will trigger a macro at a Start Line address at a regularly timed interval. There
are 2 timers available. You can use this timer to trigger a macro line that starts the ID, if you want to have a beacon ID.

SYNTAX: 42 [Timer] [Start Line] [Time]

STORAGE:

RAM/EEPROM

PARAMETERS: Timer 1–2 = Timer number

Start Line 000 = Disable this function, 001 – 255 Macro data start line.
Time 0 = Reset timer, 1–255 in 6 second increments (1 to 25.5 minutes).

DEFAULT: All timers, Start Line = 000, Time = 0.

EXAMPLE: 42 1 123 100 Timer 1 will trigger macro starting at line number 123 every 10.0 minutes.

42 2 000 0

Disable timer 2.

S-Cmd 43 RESERVED