Tuning guidelines, Tuning the black level and column balancing, Chapter 4 tu – Sumix SMX-160x User Manual

Page 31: Uning, Uidelines, Chapter 4

Advertising
background image

Tuning Guidelines

31

Chapter 4

T

UNING

G

UIDELINES

Before you start working with a SMX-160 Series camera, some initial tuning should be
done to remove distortions and noise from the video view.

It is convenient to have camera histogram opened while tuning the image because you
can observe how your changes are reflected in the histogram.

Quality of the image directly depends on such parameters:

Black level (Amplifier DAC raw offset)

Column balancing (Amplifier DAC fine offset)

White Balance for the SMX-160C (color) model

These parameters should be always tuned at the beginning of the camera work. Besides,
each time when the Black level and Column balancing are changed, the White Balance
should be tuned as well.

Concerning the environment conditions, day lighting is the best condition for the colors
and image tuning. Otherwise, use additional fluorescent light or its equivalent.

Tuning the Black Level and Column Balancing

To adjust Black level and Column balancing:

1

Start video by pressing the Start Video

button in the toolbar.

2

Activate histogram by pressing h on the keyboard.

Figure 4-1 Histogram view before tuning image

3

Go to the Sensor Control section of the main window and set:

a.

frequency to 40 MHz

b.

exposure to its maximal value

c.

gain to 0 dB

Advertising