Super Systems 9120 User Manual

Page 12

Advertising
background image

4574 - SSi 9120 Manual Rev A

Page 12

Super Systems Inc

Note: This menu item is also located later in the manual under the

Section 1 – 9120 Configurator Menus

section

.

The 9120 controller has two analog inputs. Each of the inputs comes with a factory default configuration dependent on
the application (refer to PVT type under the

Furnace Setup

section). It can be modified prior to shipment to your facility

or in the field by a technician or qualified/trained person with the proper security code.

Analog Input Terminals
Analog Input 1 – terminals 31 and 32
Analog Input 2 – terminals 29 and 30

Parameter Definitions
Input Type
The thermocouple type for most applications can be modified depending on your specific needs. Please note that in some
applications, some of the inputs DO NOT allow the user to modify the Input type.

Note: Before changing the input type,

make sure to set the appropriate jumpers, if necessary

.

The jumper will need to be manually changed on the input board

before changing the input type to a 10:1 setting (non-thermocouple types)

. To change the Input type, first select which

input you want to change by selecting it in the pull-down menu just below the main menu list. Clicking on the Value will
display an input box, and then you can use the pull-down menu to select the desired parameter. Once selected, click

OK

and the displayed Input type under Value will be the current type.

The following is a list of the options:
B

S

12.5 volts

C

T

781.25mv

E

2.5 volts

195.3125 mV

J

1.25 volts

K

78.125 mV

N

19.53125 mV

NNM

4-20 mA

R

25 volts


Filter time
The filter time is a factory applied averaging tool used to help maintain steady control in high EMI environments. The
filter time should not be adjusted with consulting SSI. Clicking on this value will display an input box from which the user
can select a new value. The range is 0 to 32767.

Initial Scale
This is the initial scale value. Clicking on this value will display an input box from which the user can select a new value.
The range is –32768 to 32767.

Full scale
This is the full scale value. Clicking on this value will display an input box from which the user can select a new value.
The range is –32768 to 32767.

Decimal Point Location
This is the decimal point location value. Clicking on this value will display an input box from which the user can select a
new value. The range is 0 to 4.

Open TC
This is the open TC value. Clicking on this value will toggle between up scale, and down scale.

Input Offset
The input offset value is algebraically added to the input value to adjust the input curve on read-out.

Note: The input

offsets are unscaled

. The range is –5000 to 5000.