Clicking on the “Value” area next to this field will

manually

cancel a probe burnoff. The

user will have to confirm the cancellation.

Next Burnoff In (shown in minutes)
This value is a displayed calculation based on the burnoff time set in the

Burnoff Setup

menu option. It displays the number of minutes until the next burnoff will be initiated.

Test Status
This value displays the current testing status. The list of possible values are: Burnoff, Burnoff Recovery, or Idle.

Timer (sec)
This value shows the remaining time, in seconds, for the Burnoff / Recoveries.

MV
This value is a display of the current millivolt input value during a burnoff.

TC
This value is a display of the current probe thermocouple input value during a burnoff.

Start mV
This value is a display of the millivolt input value at the beginning of the Burnoff.

Start TC
This value is a display of the probe thermocouple value at the beginning of the burnoff.

Last Burnoff
This value shows the date and time of the last burnoff.

Last Min mV

This value is a display of the minimum
millivolts measured during the last burnoff.

Last Max TC
This value is a display of the maximum
measured probe thermocouple input value
during the last burnoff.






Slave Instruments

This page is a display of the current process
variables of each of the slave instruments
communicating with the 9120 controller.

Note – None of these values can be
modified on this screen

.