<SwitchB> system-view

[SwitchB] isis

[SwitchB-isis-1] network-entity 10.0000.0000.0002.00

[SwitchB-isis-1] quit

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] isis enable

[SwitchB-Vlan-interface10] quit

[SwitchB] interface vlan-interface 13

[SwitchB-Vlan-interface13] isis enable

[SwitchB-Vlan-interface13] quit

# Configure Switch C.

<SwitchC> system-view

[SwitchC] isis

[SwitchC-isis-1] network-entity 10.0000.0000.0003.00

[SwitchC-isis-1] quit

[SwitchC] interface vlan-interface 11

[SwitchC-Vlan-interface11] isis enable

[SwitchC-Vlan-interface11] quit

[SwitchC] interface vlan-interface 13

[SwitchC-Vlan-interface13] isis enable

[SwitchC-Vlan-interface13] quit

3.

Configure BFD parameters:
# Enable BFD on Switch A and configure BFD parameters.

[SwitchA] bfd session init-mode active

[SwitchA] interface vlan-interface 10

[SwitchA-Vlan-interface10] isis bfd enable

[SwitchA-Vlan-interface10] bfd min-receive-interval 500

[SwitchA-Vlan-interface10] bfd min-transmit-interval 500

[SwitchA-Vlan-interface10] bfd detect-multiplier 7

# Enable BFD on Switch B and configure BFD parameters.

[SwitchB] bfd session init-mode active

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] isis bfd enable

[SwitchB-Vlan-interface10] bfd min-receive-interval 500

[SwitchB-Vlan-interface10] bfd min-transmit-interval 500

[SwitchB-Vlan-interface10] bfd detect-multiplier 8

[SwitchB-Vlan-interface10] return

4.

Verify the configuration:
The following configurations are made on Switch A. Configurations for Switch B are similar.
(Details not shown.)
# Display the BFD information on Switch A.

<SwitchA> display bfd session

Total Session Num: 1 Init Mode: Active

Session Working Under Ctrl Mode:

LD/RD SourceAddr DestAddr State Holdtime Interface

3/1 10.1.0.102 10.1.0.100 Up 1700ms vlan10

# Display routes destined for 120.1.1.0/24 on Switch A.