Logs

Creating an Incident Template from Incident Log Viewer

170

Figure 4-90

If there are more than one GSM listed, select a GSM from the list on the left. Its Alarm
Browser appears on the right.

3. In the GSM Alarm Browser, find and select alarms upon which to base your incident

template.

Tip: Shift + click to select multiple alarms, Ctr l+ click to make a non-contiguous selection.

4. Click the down arrow.

The alarms appear in the incident template components area.

5. The table displays various details about the sub-alarms you have selected, including their

Contribution, which defines how a sub-alarm will pass its status on to the incident template.
The default contribution value is Passthrough, which means the sub-alarm will pass its
status unaltered to the overall calculation of the incident.

It is possible to override the error status of sub-alarms when they are triggered. This is useful
when, for example, a device is only able to report a status of either

normal 

(green) or

error

(red), but you want the error condition to be reflected as a

warning

(yellow) in the incident

template. To change a sub-alarm’s contribution, click in the Contribution column, and then
select the status you want the incident template to use when an error occurs.

Incident template

components

Selected alarms in GSM

Alarm Browser

Click to add alarms to

template

Advertising