20.2.27 TOOL LENGTH MEASUREMENT

# 30074, RET # 30075, TLMO # 35051)

These inputs and outputs are used with tools mounted on the Z-axis when the manually moved
distance from the predetermined reference position to the reference level is written into the
tool correction value memory directly and automatically.

These inputs and outputs are provided for tool length measurement, When the TLMI is

opened, the current Z-axis value is stored in NC memory as reference position data.

this

time, the TLMO output is generated to indicate the tool length measurement mode.

When the RET is closed with the Z-axis moved to the measurement point, the distance moved

from the Z-axis reference position is stored in a memory location having a certain correction

number.

When the TLMI is opened again, system exits the TLM mode and the TLMO output falls.

v

Z-AXIS REFERENCE POSITION

Z-AXIS TRAVEL

TLMO

I

RET

THE DISTANCE BETWEEN THE Z-AXIS
REFERENCE POSITION AND MEASUREMENT

Z-AXIS REFERENCE

POSITION STORAGE

Fig. 20.10 Tool Length Measurement

Time Chart

20.2.28

SELECTION SIGNAL (FI #30076)

When a number between 1 and 9 is designated as a suffix to F, the associated predefined set-
ting parameter (Pm820-Pm828) dictates the feedrate.

When the

input is closed, rotating the manual pulse generator increases or decreases the

-digit designated feedrate.

As a result of this operation, the -digit speed setting changes.

While the

input is open, the feedrate does not vary upon manual pulse generator rotation.

2.

3.

4.

NOTE

When this function is added, the normal F function cannot be used to select a feedrate be-

tween 1 and 9

However, it can be used to select a feedrate of 10

or

higher,

While the Dry Run switch is ON, the Dry Run speed takes precedence.

The feed override function does not work on the

-digit selection signal.

The stored feedrate data are retained even after the power is turned OFF.