21.3.1.26

CURRENT VALUE STORAGE INPUT

(

PST

# 3 0 0 8 3 )

This input is used to store the current values into the control memory.

When the PST input closes, the control stores the current values into the internal memory.

The offset data written by the MDI are later operated

offset memory.

Data written

Input data

into offset memory

I

I

on as follows and then stored into the

Current value data
stored in

control memory

When the reset procedure (turning ON the MDI panel reset key or closing the external reset

input) is performed, the current value storage mode is canceled with LED blinking terminated.

NOTE

The current value storage position and procedure and offset memory

storage value computations vary with the machine.

21. 3. 1. 27

These inputs

EXTERNAL STORAGE, EXTERNAL VERIFICATION, EXTERNAL OUTPUT, AND

EXTERNAL CLEAR SIGNAL INPUTS (EIN # 30110, EVER # 30111, EOUT # 30112,

ECLM # 301 13)

are used to externally perform the storage, verification, output, or clear operation

relative to the control NC memory.

When the inputs are closed, the following operations are performed.

(When the EIN input is closed)

Part programs are stored into NC memory.

(When the EVER input is closed)

Part programs are compared against NC memory.

(When the EOUT input is closed)

The contents of NC memory are output.

(When the ECLM input is closed)

The contents of the NC memory are cleared.

While the above storage, verification, output, or clear operation is being performed, the editing

state

output is closed.

NOTE

The storage/verification 1/0 equipment varies with the setting (#0009).