Basic Operation

Saving/Recalling Settings (Memory)

You can take the current settings, including video and audio settings and the state of the operation panel, and

save them as a single set in the V-1HD’s internal memory, for later recall and use when needed. The V-1HD is

provided with eight memories.

Settings saved in memory

What you can save in memory are the MEMORY

menu and AUDIO menu settings and the state of

the operation panel.
Each uses a different method for saving its values in

memory.

MEMORY menu/AUDIO menu settings

<Procedure for Saving>

Values are saved in memory when you quit each

menu (p. 12).

State of the operation panel

State of the [OUTPUT FADE] knob
State of the [EFFECTS A] and [EFFECTS B] knobs
On/off status of the EFFECTS A and EFFECTS B [ON] buttons
[A-1] through [A-4] button selection
[B-1] through [B-4] button selection
On/off status of the [BPM SYNC] button
[MIX], [WIPE] and [CUT] button selection
State of the A/B fader

<Procedure for saving>

Turn on the memory function (lighted) and save

the state of the operation panel in memory.
For more information on how to do this, refer to

“Saving the State of the Operation Panel” on this

page.

MEMO

5

SETUP menu items are not saved in memory. Only a

single set is saved in the unit.

5

You can recall settings at a specified memory number

at startup. Press and hold the [(TAP) BPM] button

g

use

“POWER ON LOAD” at the SETUP menu to specify the

memory number you want to recall.

NOTE

To update the state of the operation panel when

recalling a memory

By default, the state of the operation panel is not

updated when you recall a memory.
To update the state of the operation panel, press and

hold the [(TAP) BPM] button

g

at the SETUP menu, set

“MEMORY PANEL LOAD” to “ON.”

Saving the state of the operation panel

This saves the state of the operation panel, including

button and knob settings, in memory.

1.

Press the [MEMORY] button to turn on the

memory function (lighted).

At this time the [A-1] through [A-4] and [B-1]

through [B-4] buttons function as memory

selection buttons 1 through 8.
The currently selected button lights up in blue.

2.

Press and hold the [A-1] through [A-4] or [B-1]

through [B-4] button for the memory number

where you want to save the settings.

Memory number

1–4

5–8

The [A-1] through [A-4] and [B-1] through [B-4]

buttons all briefly light up in blue, and the

current settings are saved.

3.

To turn off the memory function, press the

[MEMORY] button again.

Recalling a memory

1.

Press the [MEMORY] button to turn on the

memory function (lighted).

2.

Press the [A-1] through [A-4] or [B-1] through

[B-4] button for the memory number you want

to recall.

The settings are recalled. The currently selected

button lights up in blue.

3.

To turn off the memory function, press the

[MEMORY] button again.

Advertising