Rosemount 5300 series, Reference manual – Emerson Process Management ROSEMOUNT 5300 User Manual

Page 216

Advertising
background image

Reference Manual

00809-0100-4530, Rev BA

July 2009

Rosemount 5300 Series

A-32

Spare parts list Probe Model 5301/5302/5303

Model

Product Description

5309

Spare probe

Code

Signal Output

N

Not Applicable

Code

Housing Material

N

Not Applicable

Code

Conduit / Cable Threads

N

Not Applicable

Code

Operating Temperature and Pressure

(1)

Probe Type

S

- 15 psig (-1bar) to 580 psig (40 bar) @ 302 °F (150 °C)

All

H

High Temp / High Pressure

(2)

:

2940 psi @ 752 °F and 5000 psi @ 100 °F (203 bar @ 400 °C and
345 bar @ 38 °C) according to ANSI Class 2500

3A, 3B, 4A, 4U, 4V, 5A and 5B

P

High Pressure

(2)

:

Max 392 °F (200 °C): 3500 psi @ 392 °F and 5000 psi @ 100 °F (243 bar @
200 °C and 345 bar @ 38 °C) according to ANSI Class 2500

3A, 3B, 4A, 5A and 5B

C

Cryogenic Temperature

(2)

(3)

-321 °F (-196 °C)

Max 392 °F (200 °C): 3500 psi @ 392 °F and 5000 psi @ 100 °F (243 bar
@ 200 °C and 345 bar @ 38 °C) according to ANSI Class 2500

3A, 3B, 4A, 5A, 5B (only SST)

Code

Material of Construction

(4)

: Process

Connection / Probe

Probe Type

Valid Operation Temperature and Pressure

1

316 L SST (EN 1.4404)

All

S, H, P, C

2

Alloy C-276 (UNS N10276). With plate
design if flanged version. Up to class 600,
PN 63 for HTHP/HP probes.

3A, 3B, 4A

S, H, P

3

Alloy 400 (UNS N04400). With plate
design if flanged version.

3A, 3B, 4A, 5A, 5B

S

7

PTFE covered probe and flange. With
plate design.

4A and 5A

S

8

PTFE covered probe.

4A and 5A

S

H

Alloy C-276 (UNS N10276) process
connection, flange and probe

(5)

3A, 3B, 4A

H, P

Code

Sealing, O-ring Material (Consult factory for other o-ring materials)

N

None

(6)

V

Viton

®

fluoroelastomer

E

Ethylene Propylene

K

Kalrez

®

6375 perfluoroelastomer

B

Buna-N

Code

Probe Type

Process Connection

Probe Lengths

1A

Rigid Twin Lead

(7)

Flange / 1.5 in., 2 in.

(7)

Thread

Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)

2A

Flexible Twin Lead with weight

(7)

Flange / 1.5 in., 2 in.

(7)

Thread

Min: 3 ft 4 in. (1 m). Max: 164 ft (50 m)

3A

Coaxial (for level measurement)

(8)

Flange / 1 in.

(7)

, 1.5 in., 2 in.

(7)

Thread

Min: 1 ft 4 in. (0.4 m). Max: 19 ft 8 in. (6 m)

3B

Coaxial, perforated. For level and interface
measurement, or easier cleaning.

Flange / 1 in.

(7)

, 1.5 in., 2 in.

(7)

Thread

Min: 1 ft 4 in. (0.4 m). Max: 19 ft 8 in. (6 m)

4A

Rigid Single Lead (8 mm)

Flange / 1 in.

(7)

, 1.5 in., 2 in.

(7)

Thread / Tri-Clamp

Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)

4B

Rigid Single Lead (13 mm)

(9)

Flange / 1 in., 1.5 in., 2 in. Thread
/ Tri-Clamp

Min: 1 ft 4 in. (0.4 m). Max: 14 ft 9 in. (4.5 m)

4U

Vapor Single Rigid Probe for 2 in. pipes

(10)

Flange / 1.5 in. Thread

Min: 2 ft 5 in. (0.76 m). Max: 13 ft (4 m)

Advertising