Rosemount 5300 series, Reference manual – Emerson Process Management ROSEMOUNT 5300 User Manual

Page 293

Advertising
background image

Reference Manual

00809-0100-4530, Rev BA
July 2009

G-3

Rosemount 5300 Series

DB_REG_2_FLOAT

49

If the register contains a float value, it should be displayed here

DB_REG_2_INT_DEC

50

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

DB_REG_3_TYPE

51

Register type

DB_REG_3_FLOAT

52

If the register contains a float value, it should be displayed here

DB_REG_3_INT_DEC

53

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

DB_REG_4_TYPE

54

Register type

DB_REG_4_FLOAT

55

If the register contains a float value, it should be displayed here

DB_REG_4_INT_DEC

56

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

DB_REG_5_TYPE

57

Register type

DB_REG_5_FLOAT

58

If the register contains a float value, it should be displayed here

DB_REG_5_INT_DEC

59

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

DB_REG_6_TYPE

60

Register type

DB_REG_6_FLOAT

61

If the register contains a float value, it should be displayed here

DB_REG_6_INT_DEC

62

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

DB_REG_7_TYPE

63

Register type

DB_REG_7_FLOAT

64

If the register contains a float value, it should be displayed here

DB_REG_7_INT_DEC

65

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

DB_REG_8_TYPE

66

Register type

DB_REG_8_FLOAT

67

If the register contains a float value, it should be displayed here

DB_REG_8_INT_DEC

68

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

DB_REG_9_TYPE

69

Register type

DB_REG_9_FLOAT

70

If the register contains a float value, it should be displayed here

DB_REG_9_INT_DEC

71

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

DB_REG_10_TYPE

72

Register type

DB_REG_10_FLOAT

73

If the register contains a float value, it should be displayed here

DB_REG_10_INT_DEC

74

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

RM_COMMAND

75

Used to set what will be read or write from a secondary master.

RM_DATA

76

Data read/write from secondary master.

RM_STATUS

77

Status read by a secondary master.

Parameter

Index

Number

Description

Advertising