Transition zones -10, Rosemount 5300 series, Reference manual – Emerson Process Management ROSEMOUNT 5300 User Manual

Page 24: Transition zones

Advertising
background image

Reference Manual

00809-0100-4530, Rev BA

July 2009

Rosemount 5300 Series

2-10

Transition Zones

The measuring range depends on probe type and product properties, and is
limited by the Upper and Lower Transition Zones. In these zones,
measurement accuracy may be reduced. The Upper Transition Zone is the
minimum measurement distance between the upper reference point and the
product surface. At the end of the probe, the measuring accuracy is reduced
in the Lower Transition Zone. The Transition Zones vary depending on
probe type and product.

Figure 2-7 illustrates how the measuring range is related to the Transition
Zones:

Figure 2-7. Transition Zones

NOTE!
Measurements in the Transition Zones may be non-linear, or have reduced
accuracy. It is recommended the 4-20 mA points be set between the
Transition Zones.

Table 2-2. Transition Zones for
different probe types and dielectric
constants

Dielectric
Constant

Rigid Single Lead

Flexible Single Lead

Coaxial

Rigid Twin Lead

Flexible Twin Lead

Upper

(1)

Transition
Zone

80

4.3 in. (11 cm)

4.3 in. (11 cm)

4.3 in. (11 cm)

4.3 in. (11 cm)

4.7 in. (12 cm)

2

6.3 in. (16 cm)

7.1 in. (18 cm)

4.3 in. (11 cm)

5.5 in. (14 cm)

5.5 in. (14 cm)

Lower

(2)

Transition
Zone

80

2 in. (5 cm)

0 in. (0 cm)

(4)(3)

0.4 in. (1 cm)

1.2 in. (3 cm)

2 in. (5 cm)

(4)

2

2.8 in. (7 cm)

(5)

2 in. (5 cm) - long weight

(4)

3.2 in. (8 cm) - short weight

(4)

2 in. (5 cm)

4 in. (10 cm)

5.5 in. (14 cm)

(4)

(1) The distance from the upper reference point where measurements have reduced accuracy, see picture above.
(2) The distance from the lower reference point where measurements have reduced accuracy, see picture above.
(3) The measuring range for the PTFE covered Flexible Single Lead probe includes the weight. For low dielectric media, special configuration may be

required.

(4) Note that the weight length adds to non-measurable area and is not included in the table. See “Dimensional Drawings” on page A-9.
(5) If using a metal centering disc, the lower transition zone is up to 8 in. (20 cm). If using a PTFE centering disc, the lower transition zone is not affected.

4mA

20mA

Upper Transition Zone

Lower Transition Zone

Range 0

-100 %

Maximum
Recommended
Measuring Range

Upper Reference Point