Reference Manual

00809-0100-4530, Rev BA

July 2009

Rosemount 5300 Series

B-14

CANADIAN STANDARDS
ASSOCIATION (CSA)
APPROVAL

This product meets the Dual Seal Requirements of ANSI/ISA 12.27.01-2003.

Dual seal annunciation

The breach of the secondary seal is annunciated via product leakage from the
antenna’s vents. The leakage will be visible and/or audible from the
transmitter head’s threads.

Dual seal maintenance

No maintenance required. Verify proper operation by keeping leak path free

from ice or contamination.

Cert. no. 1514653.

Intrinsic Safety

Figure B-14. Approval Label
Canadian Standards Association
(CSA) HART model

I6

Intrinsically Safe Ex ia.

Class I, Division 1, Groups A, B, C and D.

Temperature code T4.

4-20 mA/HART model: U

i

=30 V, I

i

=130 mA, P

i

=1.0 W, C

i

=7.26 nF, L

i

=0 H.

Installation Drawing: 9240 030-937.

Ambient temperature limits: -50

°

C to + 70

°

C.