Rosemount 5300 series, Reference manual – Emerson Process Management ROSEMOUNT 5300 User Manual

Page 292

Advertising
background image

Reference Manual

00809-0100-4530, Rev BA

July 2009

Rosemount 5300 Series

G-2

XD_ERROR

11

A transducer block alarm subcode.

COLLECTION_DIRECTORY

12

INP_SEARCH_START_NBR

13

Search start number for input registers

DB_SEARCH_START_NBR

14

Search start number for holding registers

INP_REG_1_TYPE

15

Register type

INP_REG_1_FLOAT

16

If the register contains a float value, it should be displayed here

INP_REG_1_INT_DEC

17

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

INP_REG_2_TYPE

18

Register type

INP_REG_2_FLOAT

19

If the register contains a float value, it should be displayed here

INP_REG_2_INT_DEC

20

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

INP_REG_3_TYPE

21

Register type

INP_REG_3_FLOAT

22

If the register contains a float value, it should be displayed here

INP_REG_3_INT_DEC

23

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

INP_REG_4_TYPE

24

Register type

INP_REG_4_FLOAT

25

If the register contains a float value, it should be displayed here

INP_REG_4_INT_DEC

26

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

INP_REG_5_TYPE

27

Register type

INP_REG_5_FLOAT

28

If the register contains a float value, it should be displayed here

INP_REG_5_INT_DEC

29

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

INP_REG_6_TYPE

30

Register type

INP_REG_6_FLOAT

31

If the register contains a float value, it should be displayed here

INP_REG_6_INT_DEC

32

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

INP_REG_7_TYPE

33

Register type

INP_REG_7_FLOAT

34

If the register contains a float value, it should be displayed here

INP_REG_7_INT_DEC

35

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

INP_REG_8_TYPE

36

Register type

INP_REG_8_FLOAT

37

If the register contains a float value, it should be displayed here

INP_REG_8_INT_DEC

38

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

INP_REG_9_TYPE

39

Register type

INP_REG_9_FLOAT

40

If the register contains a float value, it should be displayed here

INP_REG_9_INT_DEC

41

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

INP_REG_10_TYPE

42

Register type

INP_REG_10_FLOAT

43

If the register contains a float value, it should be displayed here

INP_REG_10_INT_DEC

44

If the register contains a DWORD value, and dec is chosen,
it should be displayed here

DB_REG_1_TYPE

45

Register type

DB_REG_1_FLOAT

46

If the register contains a float value, it should be displayed here

DB_REG_1_INT_DEC

47

If the register contains a DWORD value, and dec is chosen, it
should be displayed here

DB_REG_2_TYPE

48

Register type

Parameter

Index

Number

Description

Advertising