11 pwm output control register, Pwm output control register – Freescale Semiconductor MC68HC908MR32 User Manual

Page 154

Advertising
background image

Pulse-Width Modulator for Motor Control (PWMMC)

MC68HC908MR32 • MC68HC908MR16 Data Sheet, Rev. 6.1

154

Freescale Semiconductor

DT2 — Dead-Time 2 Bit

Current sensing pin IS1 is monitored immediately before dead-time ends due to the assertion of
PWM2.

DT1 — Dead-Time 1 Bit

Current sensing pin IS1 is monitored immediately before dead-time ends due to the assertion of
PWM1.

12.9.11 PWM Output Control Register

The PWM output control register (PWMOUT) is used to manually control the PWM pins.

OUTCTL— Output Control Enable Bit

This read/write bit allows the user to manually control the PWM pins. When set, the PWM generator is
no longer the input to the dead-time and output circuitry. The OUTx bits determine the state of the
PWM pins. Setting the OUTCTL bit does not disable the PWM generator. The generator continues to
run, but is no longer the input to the PWM dead-time and output circuitry. When OUTCTL is cleared,
the outputs of the PWM generator immediately become the inputs to the dead-time and output circuitry.

1 = PWM outputs controlled manually
0 = PWM outputs determined by PWM generator

OUT6–OUT1— PWM Pin Output Control Bits

These read/write bits control the PWM pins according to

Table 12-10

.

Address: $0025

Bit 7

6

5

4

3

2

1

Bit 0

Read:

0

OUTCTL

OUT6

OUT5

OUT4

OUT3

OUT2

OUT1

Write:

Reset:

0

0

0

0

0

0

0

0

= Unimplemented

Figure 12-46. PWM Output Control Register (PWMOUT)

Table 12-10. OUTx Bits

OUTx Bit

Complementary Mode

Independent Mode

OUT1

1 — PWM1 is active.
0 — PWM1 is inactive.

1 — PWM1 is active.
0 — PWM1 is inactive.

OUT2

1 — PWM2 is complement of PWM 1.
0 — PWM2 is inactive.

1 — PWM2 is active.
0 — PWM2 is inactive.

OUT3

1 — PWM3 is active.
0 — PWM3 is inactive.

1 — PWM3 is active.
0 — PWM3 is inactive.

OUT4

1 — PWM4 is complement of PWM 3.
0 — PWM4 is inactive.

1 — PWM4 is active.
0 — PWM4 is inactive.

OUT5

1 — PWM5 is active.
0 — PWM5 is inactive.

1 — PWM5 is active.
0 — PWM5 is inactive.

OUT6

1 — PWM 6 is complement of PWM 5.
0 — PWM6 is inactive.

1 — PWM6 is active.
0 — PWM6 is inactive.

Advertising