16.7.3 TIMA Counter Modulo Registers

The read/write TIMA modulo registers contain the modulo value for the TIMA counter. When the TIMA
counter reaches the modulo value, the overflow flag (TOF) becomes set, and the TIMA counter resumes
counting from $0000 at the next timer clock. Writing to the high byte (TAMODH) inhibits the TOF bit and
overflow interrupts until the low byte (TAMODL) is written. Reset sets the TIMA counter modulo registers.

NOTE

Reset the TIMA counter before writing to the TIMA counter modulo registers.

16.7.4 TIMA Channel Status and Control Registers

Each of the TIMA channel status and control registers:

Flags input captures and output compares

Enables input capture and output compare interrupts

Selects input capture, output compare, or PWM operation

Selects high, low, or toggling output on output compare

Selects rising edge, falling edge, or any edge as the active input capture trigger

Selects output toggling on TIMA overflow

Selects 0 percent and 100 percent PWM duty cycle

Selects buffered or unbuffered output compare/PWM operation

Register Name and Address:

TAMODH — $0011

Bit 7

6

5

4

3

2

1

Bit 0

Read:

Bit 15

Bit 14

Bit 13

Bit 12

Bit 11

Bit 10

Bit 9

Bit 8

Write:

Reset:

1

1

1

1

1

1

1

1

Register Name and Address:

TAMODL — $0012

Bit 7

6

5

4

3

2

1

Bit 0

Read:

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Write:

Reset:

1

1

1

1

1

1

1

1

Figure 16-7. TIMA Counter Modulo Registers