12.9.3 PWMx Value Registers

Each of the six PWMs has a 16-bit PWM value register.

The 16-bit signed value stored in this register determines the duty cycle of the PWM. The duty cycle is
defined as: (PWM value/modulus) x 100.

Writing a number less than or equal to 0 causes the PWM to be off for the entire PWM period. Writing a
number greater than or equal to the 12-bit modulus causes the PWM to be on for the entire PWM period.

If the complementary mode is selected, the PWM pairs share PWM value registers.

To avoid erroneous PWM pulses, this value is buffered and will not be used by the PWM generator until
the LDOK bit has been set and the next PWM load cycle begins.

NOTE

When reading these registers, the value read is the buffer (not necessarily
the value the PWM generator is currently using).