19.12 CGM Acquisition/Lock Time Specifications

Description

Symbol

Min

Typ

Max

Notes

Filter capacitor multiply factor

C

FACT

0.0154

F/sV

Acquisition mode time factor

K

ACQ

0.1135

V

Tracking mode time factor

K

TRK

0.0174

V

Manual mode time to stable

t

ACQ

(8*V

DDA

)/

(f

XCLK

*K

ACQ)

If C

F

chosen

correctly

Manual stable to lock time

t

AL

(4*V

DDA

)/

(f

XCLK

*K

TRK

)

If C

F

chosen

correctly

Manual acquisition time

t

Lock

t

ACQ

+t

AL

Tracking mode entry frequency
tolerance

TRK

0

± 3.6%

Acquisition mode entry frequency
tolerance

ACQ

±

6.3%

± 7.2%

Lock entry frequency tolerance

Lock

0

± 0.9%

Lock exit frequency tolerance

UNL

±

0.9%

± 1.8%

Reference cycles per acquisition mode
measurement

n

ACQ

32

Reference cycles per tracking mode
measurement

n

TRK

128

Automatic mode time to stable

t

ACQ

n

ACQ

/f

XCLK

(8*V

DDA

)/

(f

XCLK

*K

ACQ)

If C

F

chosen

correctly

Automatic stable to lock time

t

AL

n

TRK

/f

XCLK

(4*V

DDA

)/

(f

XCLK

*K

TRK

)

If C

F

chosen

correctly

Automatic lock time

t

Lock

t

ACQ

+t

AL

PLL jitter (deviation of average bus
frequency over 2 ms)

f

J

0

±

(f

XCLK

)

*(0.025%)

*(N/4)