Setting digital input [“digital in – Fostex VF160EX User Manual

Page 141

Advertising
background image

141

1. Select “Digital In” in the menu selection display and press

the [ENTER/YES] key.

The items currently set will be shown in reversed white
and black (In the initial state, “

Analog

” will be reversed

in white and black).

In the [Setting digital input] menu, whether the signal assigned to tracks 1 through 16 are digital signals (adat
digital signal/SP DIF digital signal) or analog signals, can be setup.
By using this function, it becomes possible to digitally record from external digital equipment (CD, MD, DAT,
adat, digital mixer, etc.). If “S/P DIF” is selected for input of digital, the S/P DIF signal (L, R) applied to DIGITAL/
DATA INPUT of VF160EX, it will be assigned to any two tracks, and if “adat” is selected, the adat signals will be
assigned to tracks 1 through 8. If it is set to “Analog”, analog signals input to the mixer will be assigned to tracks
1 through 16.

2. Select the desired “digital in” with the [JOG] dial.

Depending on the item selected, the following will be
shown in the LCD.

• AT SELECTION OF “SPDIF”

When in the initial setup and selecting “

SPDIF

,”

simultaneous with indicating that L of the S/P DIF digital
signal is assigned to track 1 and that R to track 2, “

<-REW

F FWD->

” will also be shown.

This is indicating that any track can be selected for
assigning to L/R. If the

[REWIND]

key or

[F FWD]

key is

pressed, the blinking “L**” or “R**” will move.
If the

[JOG]

dial is rotated, numbers 1 through 16 can be

input at the blinking point.
When selecting “

SPDIF

,” because S/P DIF digital signals

can be assigned to any two tracks within 1 through 16,
simultaneous recording of S/P DIF digital signal + analog
signal is possible by input of analog signals into the other
tracks (Refer to “Chapter 5 Features Applications” for
details).

4. Press the [EXIT/NO] key (or STOP key) to exit from the

SETUP mode.

• AT SELECTION OF “adat”

At selection of “

adat

,” adat digital signals (1-8) only will

be assigned to tracks 1-8 and analog signals can be input
to tracks 9-16. As adat digital signals can be input to
tracks 1-8 and analog signals into tracks 9-16 by using
this feature, simultaneous recording of analog/digital 16
tracks can be realized. For details, refer to “Chapter 5
Features Applications.”

<Note>

If set to “S/P DIF or adat, “DIGITAL” will be lit in the display
when the DIGITAL/DATA INPUT is locked.
Should “DIGITAL” blink, check the connecting cables
between external equipment and recheck the setups of
VF160EX and external equipment.

• Initial setting:

“Analog”

• Options:

“Analog”, “adat”, or
“SPDIF” (L=1~16, R=1~16)

* You can set the mode for each Program individually.
* The settings can be saved and loaded as part of the

song data.

* The settings are maintained after you turn off the

power to the VF160EX.

When a correct digital signal (adat or S/P DIF) is input
from the external digital equipment and then VF160EX
is locked to the input signal, "ADAT" or "SPDIF" will be
lit in the normal display as shown below.
If this display blinks, it indicating that an incorrect digi-
tal signal is input to the VF160EX. In such a case, check
connections between any external equipment or the ex-
ternal equipment digital out setting.

At setting of “ADAT”

At setting of “SPDIF”

If you set the digital input to "

SPDIF

", and press the

[ENTER/YES]

key you will see a copyright warning.

You can read the entire message by rotating the

[JOG]

dial. If you accept, press the

[ENTER/YES]

key again.

3. Select the desired “digital in” and press the [ENTER/YES]

key.

The selected “

digital in

” will be setup.

Setting Digital Input [“Digital In”]