St - serial test, Serial test -74 – GE 68K System User Manual

Page 100

Advertising
background image

GE Energy Services

68K System Monitor

User's Guide

SWM0023 1.00 2

General

3-74

Full Release

ST - Serial Test

Platform

þ

CPM

þ

D20
D20 Base

þ

D20 ME
D20 Base

þ

D20/200
CCU Base

þ

D20/200 ME
CCU Base

þ

D25

Description

Use this command to start one of these two serial port test procedures:
• an automatic loop-back test of the defined serial port

− transmits and receives a series of characters of different formats.

• manually forcing the mark or space line states from the RS-232 drivers

− allows you to monitor and adjust modem levels or frequencies.

Syntax

Below is usage and syntax information for this command

Command Format

CPM / D20: st /(f | l) port

CCU / CCUME / D25: st /(f | l) port [baud]

Variables

/f

= force mark or space states

/l

= automatic loop-back test

Parameters

port

= serial port to test (COM#)

baud

= data rate in bps (decimal)

Example

Type st /l com7 9600 and press

ENTER

.

Results: This forces the RS-232 transmitter driver for

communications port seven (7) to perform the loop-
back test at 9600 bps.

The system displays the current state of the test.
Cancel the force test manually with

CTRL

-

C

.

The loop-back test terminates either on an error or on
completion of the test. The monitor displays the
prompt after stopping either test.

Special
Considerations

• These tests temporarily assume control of the specified

communications port, and disrupt any current activity.

• They may also, depending on the application, affect

subsequent operation.

To ensure that you avoid this, you must reboot the system
when you complete all testing.

Continued on next page