background image

GE Energy Services

68K System Monitor

User's Guide

SWM0023 1.00 2

General

3-20

Full Release

D - Dump Memory,

Continued

Syntax (continued)

Example

Type d /w f024 and press

ENTER

.

Results: The system displays the specified data (eight lines

consisting of address, eight hexadecimal words, and
16 ASCII characters, starting at hexadecimal address
F024), then displays the prompt.

Type d and press

ENTER

.

Results: The system displays the next eight lines starting at

hexadecimal address F024+80=F0A4, then displays
the prompt.

Special
Considerations

• An attempt to display non-existent memory results in a bus

error.

• If this is the first dump, not specifying any parameters will

return an error.