Ccb - create configuration storage block – GE 68K System User Manual

Page 39

Advertising
background image

68K System Monitor
User's Guide

GE Energy Services

General

SWM0023-1.00 -2

Full Release

3-13

CCB - Create Configuration Storage Block,

Continued

Parameters (continued)

Example

Type ccb 600000 100000 400 2 and press

ENTER

.

Results: The monitor creates a configuration storage control

block at address 0x600000, taking the next 0x100000
bytes as the space for the configuration storage
system.

After allocating the size of the storage control
structures and the 0x400 bytes for the response file,
the command divides the remaining space into two
equal slices to store configurations.

Special
Considerations

Use this command primarily when the system first initializes,
in order to set up the configuration storage space. After that, it
expects to be only rarely invoked.

Advertising