Unit installation – Garland JACK IN THE BOX XG36-JIB User Manual

Page 10

Advertising
background image

Part # JIBSM08 Rev 7 (08/04/09)

Page 10

UNIT INSTALLATION

continued

The grill must be disconnected from the gas supply system

when pressure testing of that system at pressures in excess of

1/2 psi (3.45kPa).

Check the data plate to determine the proper type of gas

before connecting the quick disconnect or piping from the

building gas supply.

An incoming gas pressure test nipple is provided on the

incoming gas manifold for pressure checks.

Minimum incoming gas pressure for Natural Gas is 6" W.C.

Maximum incoming gas pressure for Natural Gas is 13" W.C.

Minimum incoming gas pressure for Propane is 10" W.C.

Maximum incoming gas pressure for Propane is 13" W.C.

Burner operating gas pressure can be checked at the outlet

side of the gas valve at the pressure test point.

Burner manifold pressure for Natural Gas must be 3.2" W.C.;

Burner pressure for Propane must be 3.5" W.C.

To adjust the burner pressure, remove the sealing screw

from the pressure test nipple, connect a manometer, remove

the sealing cap on the gas valve regulator, turn on the grill,

adjust the screw in the regulator to give the correct pressure,

turn off the grill, refit the regulator sealing cap, remove the

manometer, replace the seal screw in the test nipple and test

for gas leaks.

Gas pressures should be checked by the local Gas Company

or an authorized service agency only.

Test all piping and connections for gas leaks. A rich soap

solution should be used for this purpose. Never use a flame.

Appliances Equipped with Casters:

1. The installation shall be made with a connector that

complies with the Standard for Connectors for Moveable

Gas Appliances, ANSI Z21.69/CSA 6.16, Addenda Z21.69B-

2006/CSA 6.16B-2006 (or latest edition), and a quick-

disconnect device that complies with the Standard for

Quick Disconnects for Use with Gas Fuel, ANSI Z21.41/

CSA 6.9, Addenda Z21.41A-2005/CSA 6.16A-2005 (or

latest edition).

2. The front casters on the appliance are equipped with

brakes to limit the movement of the appliance without

placing any strain on the connector or quick-disconnect

device or its associated piping.

3. Please be aware; required restraint is attached to a

bracket (which is located on the rear caster closest to the

gas connection), and if disconnection of the restraint

is necessary; be sure to reconnect the device after the

appliance has been returned to its original position.

Electrical Connections:

All electrically operated appliances must be electrically

grounded in accordance with local codes; or in the absence

of local codes, with the latest edition of National Wiring

Regulations. A wiring diagram is located on the rear panel of

the grill. See rating plate in rear of grill, or lower front panel

for proper voltages.

Accessory Kit – Main Gas Inlet:

(Accessory kit part numbers 4524785 or 4525509 and also

includes electrical supply lines, see next section) .

Each griddle is supplied with an extended rear gas manifold

kit., with the following parts.

DESCRIPTION

PART DRAWING QTY.

3/4”x 3/4” 90 Degree Elbow

1

Nipple Assembly

1

Manifold Support Bracket

1

10-24 x 1/2 Quadrex

Pan HD Type F Screw

4

Installation of Kit:

A. Install the elbow on the end of manifold (3/4” NPT)

underneath the griddle, tighten and align with the elbow

facing the back of the unit. Refer to Photo A.

Photo A

Advertising
This manual is related to the following products: