Technical troubleshooting, Controller displays “probe error, Continued – Garland JACK IN THE BOX XG36-JIB User Manual

Page 39

Advertising
background image

Part # JIBSM08 Rev.6 (08/04/09)

Page 39

Controller displays “PROBE ERROR”

NO

YES

YES

YES

NO

NO

YES

NO

NO

YES

See Technical

Troubleshooting -

“HEATING ERROR”

Controller displays “Probe

ERROR” when grill is turned

on.

Controller displays “Probe

ERROR” during normal operation.

Disconnect suspected

thermocouple and check

continuity.

Has suspected

zone overheated?

Check all connections on

thermoscouple interface

board.

Compare Millivolt reading of

suspect thermocouple

will Millivolt chart.

Replace effected

zone thermocouple.

Replace damaged thermocouple

Re-establish

positive connection

TECHNICAL TROUBLESHOOTING

continued

Advertising